7-98 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

P-0-4014, Type of construction of motor<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

By this parameter the controller is informed of control-relevant features of<br />

the connected motor, such as<br />

• functional principle<br />

• type of construction<br />

• encoder data memory<br />

See also Functional Description "General Information on the Operation of<br />

Motors with <strong>Indra<strong>Drive</strong></strong>"<br />

P-0-4022, <strong>Drive</strong> address of serial interface<br />

Input min/max: Default value: Unit:<br />

MPB: 1 / 99 256 --<br />

By means of this parameter it is possible to set the address for the serial<br />

interface. This can be done via the control panel, the serial interface or<br />

the master communication interface.<br />

Note: The effective address can be directly taken from P-0-4022 or<br />

from the list P-0-4031, Overview of device addresses!<br />

See also Functional Description "Serial Communication"<br />

See also Parameter Description "P-0-4031, Overview of device<br />

addresses"<br />

P-0-4025, <strong>Drive</strong> address of master communication<br />

Input min/max: Default value: Unit:<br />

MPB: 1 / 99 --- --<br />

By means of this parameter it is possible to set the address for the master<br />

communication (e.g. SERCOS, Profibus...). This can be done via the<br />

control panel, the serial interface or the master communication interface<br />

itself.<br />

Note: The currently effective address can be directly taken from<br />

parameter S-0-0096, Slave arrangement (SLKN) or<br />

P-0-4031, Overview of device addresses!<br />

See also Functional Description "Serial Communication"<br />

P-0-4028, Device control word<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

DOK-INDRV*-FU*********-IB01-EN-P