7-60 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

P-0-0119, Best possible deceleration<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 3 0 --<br />

This parameter determines the way the drive is shut down in case<br />

• non-fatal errors occur<br />

• interface errors occur<br />

• communication phase is reset<br />

• drive enable is disabled<br />

See also Functional Description "Best Possible Deceleration"<br />

P-0-0139, Analog output 1<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 10,000 0,000 V<br />

This parameter indicates the voltage value that is output via the analog<br />

output 1 of the drive controller.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0140, Analog output 2<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 10,000 0,000 V<br />

This parameter indicates the voltage value that is output via the analog<br />

output 2 of the drive controller.<br />

See also Functional Description "Analog Outputs"<br />

P-0-0141, Thermal drive load<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0 / 100,0 --- %<br />

The P-0-0141, Thermal drive load parameter is used to check the<br />

thermal load of the amplifier, 0% of the chip overtemperature<br />

corresponding to 0 Kelvin, 100% corresponding to the maximum chip<br />

overtemperature. Given the correct dimensioning of the drive, the thermal<br />

load should not exceed the value of 80% for the intended processing<br />

cycles.<br />

P-0-0180, Acceleration feedforward smoothing time<br />

constant<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 10000 0 us<br />

This parameter allows filtering the<br />

DOK-INDRV*-FU*********-IB01-EN-P