7-106 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

See also Functional Description "PROFIBUS-DP"<br />

See also Functional Description "PROFInet"<br />

See also Functional Description "CANopen"<br />

See also Functional Description "DeviceNet"<br />

P-0-4080, Field bus: config. list of cyclic actual value<br />

data ch.<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

With this parameter the process input data channel (slave-master, i.e.<br />

"AT") is configured independent of the field bus used.<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4081, Field bus: config. list of cyclic command value<br />

data ch.<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

With this parameter the process output data channel (master-slave, i.e.<br />

"MDT") is configured independent of the field bus used.<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4082, Field bus: length of cyclic actual value data<br />

channel<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 32 2 Byte<br />

This parameter indicates the number of bytes of the process data channel<br />

parameterized in P-0-4080, Field bus: config. list of cyclic actual value<br />

data ch..<br />

This length does not contain the length parameterized in P-0-4083, Field<br />

bus: length of parameter channel of a possibly available parameter<br />

channel. The graduation takes place in word boundaries, i.e. possible<br />

values are 2, 4, 6, ... 32.<br />

Note: For communication via Interbus it is obligatory, due to the bus<br />

structure (shift register), that P-0-4071 = P-0-4082.<br />

See also Functional Description "PROFIBUS-DP"<br />

P-0-4083, Field bus: length of parameter channel<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 16 --- Byte<br />

Apart from the transmission of real-time data (also called process data),<br />

communication via a field bus also requires the transmission of<br />

DOK-INDRV*-FU*********-IB01-EN-P