<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-7<br />

Communication Phase 4<br />

Transition Check<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

• C0110 Length of MDT (S-0-0010) odd<br />

• C0111 ID9 + Record length - 1 > length MDT (S-0-0010)<br />

• C0112 TNcyc (S-0-0001) or TScyc (S-0-0002) error<br />

• C0113 Relation TNcyc (S-0-0001) to TScyc (S-0-0002) error<br />

• C0114 T4 > TScyc (S-0-0002) - T4min (S-0-0005)<br />

• C0115 T2 too small<br />

• C0116 T3 (S-0-0008) within MDT (S-0-0089 + S-0-0010)<br />

• C0139 T2 (S-0-0089) + length MDT (S-0-0010) > TScyc (S-0-<br />

0002)<br />

• If necessary, checking parameters for field bus communication for<br />

validity and compliance with requirements<br />

• C0154 Field bus: IDN for cycl. command val. not configurable<br />

• C0155 Field bus: max. length for cycl. command val. exceeded<br />

• C0156 Field bus: IDN for cycl. actual val. not configurable<br />

• C0157 Field bus: length for cycl. actual values exceeded<br />

• C0158 Field bus: Tcyc (P-0-4076) incorrect<br />

• C0159 Field bus: P-0-4077 missing for cycl. command values<br />

• Checking configuration of multiplex channel<br />

• C0118 Order of MDT configuration incorrect<br />

• C0151 IDN for command value data container not allowed<br />

• C0152 IDN for actual value data container not allowed<br />

• Limit value check of communication parameters and system<br />

• C0102 Limit error in parameter (-> S-0-0021)<br />

• C0103 Parameter conversion error (->S-0-0021)<br />

• C0131 Switching to phase 3 impossible<br />

With the S-0-0128, C0200 Communication phase 4 transition check<br />

command the following checks and initializations are carried out that can<br />

possibly cause the listed command errors:<br />

• Checking validity of parameters required for subsequent initializations<br />

• C0201 Invalid parameters (->S-0-0022)<br />

• C0212 Invalid control section data (->S-0-0022)<br />

• Checking motor and encoder configuration<br />

• C0219 Max. travel range too large<br />

• C0270 Error when reading encoder data => motor encoder<br />

• C0271 Incorrect parameterization of motor encoder (hardware)<br />

• C0272 Incorr. parameteriz. of motor enc. (mechanical system)<br />

• C0273 Modulo value for motor encoder cannot be displayed<br />

• C0274 Motor encoder unknown<br />

• C0275 Error when reading encoder data => optional encoder<br />

• C0276 Incorrect parameterization of optional enc. (hardware)<br />

• C0277 Incorr. parameteriz. of opt. enc. (mechanical system)<br />

• C0278 Modulo value for optional encoder cannot be displayed<br />

• C0279 Optional encoder unknown<br />

• C0280 Maximum travel range cannot be displayed internally<br />

• C0284 Invalid motor data in encoder memory (->S-0-0022)