<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Diagnostic and Service Functions 8-13<br />

Display at comfort control panel<br />

S-0-0095, Diagnostic message text<br />

C1216 C1216 Commutation determination not<br />

selected<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

See documentation "Troubleshooting Guide"<br />

1 2<br />

C1217 C1217 Setting only possible in 'Ab' 1 2<br />

C1218 C1218 Automatic commutation: current<br />

too low<br />

C1219 C1219 Automatic commutation:<br />

overcurrent<br />

1 2<br />

1 2<br />

Contact our sales and service facility<br />

Contact machine manufacturer / installation<br />

programmer<br />

Check motor incl. holding brake, battery, encoder and<br />

cooling system<br />

C1220 C1220 Automatic commutation: timeout 2 3 1<br />

C1221 C1221 Automatic commutation: iteration<br />

without result<br />

C1222 C1222 Error when writing offset<br />

parameters<br />

C13 C1300 Positive stop drive procedure<br />

command<br />

C1301 C1301 Class 1 diagnostics error at<br />

command start<br />

C14 C1400 Command Get marker position 1<br />

C17 C1700 Command measuring wheel mode 1<br />

C1701 C1701 Measuring wheel mode not<br />

possible<br />

C18 C1800 Command automatic control loop<br />

setting<br />

Switch supply unit off and on again<br />

Switch drive controller off and on again<br />

3 4 2 1<br />

Check encoder function and mounting (motor encoder<br />

and external encoder))<br />

4 5 2 2 1<br />

1<br />

1 2<br />

1 2<br />

C1801 C1801 Start requires drive enable 1 2<br />

C1802 C1802 Motor feedback data not valid 2 3 1<br />

C1803 C1803 Inertia detection failed 1 2<br />

C1804 C1804 Automatic controller setting failed 1 2<br />

C1805 C1805 Travel range invalid 1 2<br />

C1806 C1806 Travel range exceeded 1 2<br />

C1807 C1807 Determining travel range only via<br />

travel distance<br />

C20 C2000 Command Release motor holding<br />

brake<br />

1<br />

1 2<br />

C2001 C2001 Command not enabled 1 2<br />

C21 C2100 Brake check command 1<br />

C2101 C2101 Brake check only possible with<br />

drive enable<br />

1<br />

1 2<br />

C2103 C2103 Brake torque too low 1 3 2<br />

C2104 C2104 Command execution not possible 1 2<br />

C22 C2200 Backup working memory<br />

procedure command<br />

1<br />

Check encoder cabling<br />

Check motor cabling<br />

Check wiring of inputs and outputs and their 24V<br />

power supply<br />

Check connection of master communication<br />

Check control circuit for mains connection<br />

Check mechanical system (stiffness, loose<br />

connection,...)