8-24 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Replacing the Firmware<br />

Explanation of Terms<br />

Preparing the Firmware<br />

Replacement<br />

Note: When replacing cables, cover the open mating sites of power<br />

lines with protective caps if sprinkling with cooling<br />

liquid/lubricant or soiling may occur (allowed degree of soiling<br />

according to EN50178: 2).<br />

• replace cable<br />

CAUTION<br />

Property damage caused by bad power<br />

connectors!<br />

Only separate or connect clean and dry power<br />

⇒<br />

connectors.<br />

• connect plug-in connectors<br />

Basic Principles<br />

For firmware replacement we distinguish the following cases:<br />

• Release update<br />

An old firmware release (e.g. MPH04V06) contained in the device is<br />

replaced by a new firmware release (e.g. MPH04V08).<br />

• Version upgrade<br />

The old firmware version (e.g. MPH03V20) contained in the device is<br />

replaced by a new firmware version (e.g. MPH04V08).<br />

Note: The paragraphs below describe the recommended options of<br />

firmware replacement by higher releases ("update") or<br />

versions ("upgrade"). The same conditions and sequences of<br />

actions apply to firmware replacement by older releases or<br />

older firmware versions.<br />

Firmware for <strong>Indra<strong>Drive</strong></strong> is replaced using the following hardware and<br />

software:<br />

• MultiMediaCard (MMC)<br />

• PC with software "IndraWorks D"<br />

Note: The commissioning software "IndraWorks D" can be ordered<br />

from one of our sales and service facilities under the<br />

designation SWA-IWORKS-D**-03VRS-D0-CD650-COPY<br />

(part no. R911312495). The scope of supply of<br />

"IndraWorks D" contains a documentation which describes the<br />

operation of the program.<br />

Preparations and Conditions for Firmware Replacement<br />

You have to make the following preparations for firmware replacement:<br />

1. <strong>Drive</strong> controller must be on (24 V supply).<br />

2. Be absolutely sure to save parameter values before any firmware<br />

version upgrade (for release update this is recommended).<br />

See section "Loading, Storing and Saving Parameters"<br />

3. <strong>Drive</strong> controller mustn't be in operating mode (communication<br />

phase 4) [cf. P-0-0115].<br />

DOK-INDRV*-FU*********-IB01-EN-P