02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-32 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Firmware Upgrade with MMC<br />

(without Safety Technology)<br />

Selection Criterion<br />

Firmware Upgrade with MMC<br />

(with Safety Technology)<br />

Carrying out the firmware version upgrade with MMC requires the<br />

following steps (without safety technology):<br />

1. Load firmware<br />

Switch drive off.<br />

⇒<br />

Plug MMC with new firmware into corresponding slot at controller.<br />

⇒<br />

Restart drive with MMC plugged.<br />

⇒<br />

After drive has been booted, the following message appears:<br />

• "Firmware update?"<br />

Acknowledge this message by pressing "Enter" key of control panel.<br />

⇒<br />

By doing this, firmware is loaded from plugged MMC to controller.<br />

If drive before firmware replacement was operated without MMC<br />

plugged, the following message appears:<br />

• "Load new param.?"<br />

→ Switch drive off, remove MMC and restart drive.<br />

2. Put drive into ready-for-operation status<br />

⇒ As number of parameters to be buffered has changed, "PL" appears<br />

on display (in case errors are present, remove them first). If you now<br />

press "Esc" key, all buffered parameters are set to their default<br />

values. During this time, message "C07 Load default parameters"<br />

appears on display.<br />

3. Load parameter values<br />

Load parameter file which was saved.<br />

⇒<br />

Switch drive off and restart it (only if drive was operated with MMC<br />

⇒<br />

plugged).<br />

4. Put machine into ready-for-operation status<br />

Put machine into ready-for-operation status again according to<br />

⇒<br />

machine manufacturer's instructions.<br />

Check functions of drive.<br />

⇒<br />

Variant 2: Version Upgrade with MMC (with Safety<br />

Technology)<br />

The following requirements should have been fulfilled in order that<br />

carrying out the firmware version upgrade with MMC makes sense (with<br />

safety technology):<br />

• Controller has not been equipped with BASIC single-axis control<br />

section.<br />

• Optional slot for safety technology has been equipped with option<br />

"safety technology I/O" (S1).<br />

• Current parameter setting of axis was saved.<br />

Carrying out the firmware version upgrade with MMC requires the<br />

following steps (with safety technology):<br />

1. Load firmware<br />

Switch drive off.<br />

⇒<br />

Plug MMC with new firmware into corresponding slot at controller.<br />

⇒<br />

Restart drive with MMC plugged.<br />

⇒<br />

After drive has been booted, the following message appears:<br />

• "Firmware update?"<br />

DOK-INDRV*-FU*********-IB01-EN-P

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!