7-88 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

P-0-1122, Velocity control loop filter: bandwidth of bandstop<br />

filter<br />

Input min/max: Default value: Unit:<br />

MPB: 10,0 / 1000,0 --- Hz<br />

This parameter is used to parameterize the bandwidth of the 4 band-stop<br />

filters that can be selectively activated via P-0-1120 [n] = 2. The input<br />

value is in Hz, i.e. the actual frequency (f=1/T) is input. Notes on how to<br />

parameterize the band-stop filter are contained in the Functional<br />

Description.<br />

See also Functional Description "Velocity Loop"<br />

P-0-1123, Vel. cont. loop filter: center frequency of bandstop<br />

filter<br />

Input min/max: Default value: Unit:<br />

MPB: 4,0 / 4000,0 --- Hz<br />

This parameter is used to parameterize the center frequency of the 4<br />

band-stop filters that can be selectively activated via P-0-1120 [n] = 2. The<br />

input value is in Hz, i.e. the actual frequency (f=1/T) is input. Notes on<br />

how to parameterize the band-stop filter are contained in the Functional<br />

Description.<br />

See also Functional Description "Velocity Loop"<br />

P-0-1125, Velocity control loop: average value filter clock<br />

Input min/max: Default value: Unit:<br />

MPB: 1 / 16 1 --<br />

This parameter allows filtering the velocity control loop deviation with a<br />

moving average filter. In the case of this filter type and with constant input<br />

value, the output is always:<br />

∆Y<br />

=<br />

This means that the filter output, with constant input value, increases in a<br />

linear way and has reached its final value at the filter output after the time<br />

t = M⋅ TA. Note: This filter type therefore does not show the typical "creep<br />

behavior" (filter output increases and decreases according to<br />

an e-function!) of the usual VZ1 and VZ2 filters.<br />

X<br />

M<br />

See also Functional Description "Velocity Loop"<br />

P-0-1126, Velocity control loop: acceleration feedforward<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0000 / 214748,3647 0,0000 P-0-4014<br />

DOK-INDRV*-FU*********-IB01-EN-P