02.02.2013 Views

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

Rexroth IndraDrive C Drive Controllers HCS02.1 ... - Bosch Rexroth

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

8-22 Diagnostic and Service Functions <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Note: When replacing the motor, cover the open mating sites of<br />

power lines with protective caps if sprinkling with cooling<br />

liquid/lubricant or soiling may occur (allowed degree of soiling<br />

according to EN50178: 2).<br />

• replace motor<br />

Note: To mechanically replace the AC servo motor, observe the<br />

instructions of the machine manufacturer.<br />

• connect plug-in connectors<br />

WARNING<br />

Risk of accident due to accidental axis<br />

movement!<br />

Servo axes with indirect distance measuring system<br />

⇒<br />

via the motor encoder will loose the position data<br />

reference when the motor is replaced!<br />

This position data reference to the machine<br />

coordinate system must therefore be reestablished<br />

after replacement.<br />

• for servo axes with absolute motor encoder, reestablish the position<br />

data reference<br />

Replacing the Supply Unit<br />

Note: Replacing the unit requires, depending upon unit weight, a<br />

lifting device and an identical replacement unit.<br />

DANGER<br />

Electrical shock due to voltage-containing parts<br />

of more than 50 V!<br />

The unit may only be replaced by qualified<br />

⇒<br />

personnel, which have been trained to perform the<br />

work on or with electrical devices.<br />

Note: Prior to the replacement of the unit please check according to<br />

the type plates, whether these units are of the same types.<br />

Replace only units of the same types.<br />

Proceed as follows:<br />

1. Switch voltage to installation off and secure it against being switched<br />

back on.<br />

2. Using an appropriate measuring device, check whether the<br />

installation is power free. Wait the discharge time.<br />

3. Motors must be standing still.<br />

4. Secure vertical axes against motion.<br />

5. Release all connections from the defective unit.<br />

6. Release the fixing bolts and remove the unit from the control cabinet.<br />

Use the lifting device, if necessary.<br />

7. Hang replacement unit into mounting rails. Use the lifting device, if<br />

necessary.<br />

DOK-INDRV*-FU*********-IB01-EN-P