<strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong> Commissioning and Parameterization 7-47<br />

S-0-0301 – S-0-0400<br />

Function<br />

Function<br />

Function<br />

Function<br />

Function<br />

DOK-INDRV*-FU*********-IB01-EN-P<br />

S-0-0328, Assign list signal status word<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 31 --- --<br />

In this list parameter the assignment is made which bit of the respective<br />

parameter entered in S-0-0026, Configuration list signal status word is<br />

to be mapped to S-0-0144,Signal status word.<br />

See also Functional Description "Configurable Signal Status Word"<br />

S-0-0329, Assign list signal control word<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 31 --- --<br />

In this list parameter the assignment is made which bit of the respective<br />

parameter entered in S-0-0027, Configuration list signal control word<br />

is written via the signal control word (S-0-0145).<br />

See also Functional Description "Configurable Signal Control Word"<br />

S-0-0330, Message 'n_actual = n_command'<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter displays whether the actual velocity value has reached the<br />

command value within a tolerance window (message "n_actual =<br />

n_command").<br />