7-46 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

See also Functional Description "Motor Temperature Monitoring"<br />

S-0-0204, Motor shutdown temperature<br />

Input min/max: Default value: Unit:<br />

MPB: 155,0 S-0-0208<br />

If the motor temperature exceeds the motor shutdown temperature, the<br />

drive sets bit 2 (motor overtemperature shutdown) in S-0-0011, Class 1<br />

diagnostics and the error F2019 Motor overtemperature shutdown is<br />

generated.<br />

In the case of MHD and MKD motors, the drive sets this parameter to<br />

155 °C, in the case of MKE motors to 135 °C.<br />

See also Functional Description "Motor Temperature Monitoring"<br />

S-0-0208, Temperature data scaling type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

By means of this parameter the unit of the temperature data of the drive is<br />

determined. The values are displayed with the first decimal place.<br />

S-0-0265, Language selection<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / var. 0 --<br />

All parameter names, units and diagnostic/error messages are stored in<br />

the drive controller in several languages. This parameter determines the<br />

language of the texts to be output.<br />

• 0: German<br />

• 1: English<br />

• 2: French<br />

• 3: Italian<br />

• 4: Spanish<br />

See also Functional Description "Language Selection"<br />

S-0-0292, List of all operating modes<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

All operating modes that are supported by the drive firmware used are<br />

listed in this parameter.<br />

The codes (hexadecimal) of those operating modes are displayed that<br />

can be entered in the parameters S-0-0032 … S-0-0035 and<br />

S-0-0284 … S-0-0287 (primary mode of operation and secondary<br />

operation modes) in the form of binary values.<br />

See also Functional Description "Operating Modes"<br />