This parameter is used for setting the direct component (offset) for the<br />

selected signal (sine, square-wave, noise). The display, i.e. unit and<br />

scaling of the parameter, are set according to the assigned parameter.<br />

P-0-1155, Command value generator, amplitude<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0001 / 214748,3647 10,0000 --<br />

This parameter is used for setting the amplitude (double crest value,<br />

peak-to-peak value). The range of values of the selected signal shape<br />

(sine, square-wave, noise) is between half the plus/minus amplitude. The<br />

display, i.e. unit and scaling of the parameter, are set according to the<br />

assigned parameter.<br />

P-0-1156, Command value generator, duration 1<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 4294967,295 0,000 s<br />

This parameter is used for setting the square-wave signal. For the<br />

duration P-0-1156, Command value generator, duration 1 the<br />

command value generator output P-0-1150, Command value generator,<br />

command value is set to half the positive amplitude P-0-1155,<br />

Command value generator, amplitude plus offset P-0-1154, Command<br />

value generator, offset.<br />

When the duration 1 is over, the output of the command value generator<br />

is set to half the negative amplitude P-0-1155, Command value<br />

generator, amplitude plus offset P-0-1154, Command value generator,<br />

offset. Duration 2 starts as of this point of time.<br />

P-0-1157, Command value generator, duration 2<br />

Input min/max: Default value: Unit:<br />

MPB: 0,000 / 4294967,295 0,000 s<br />

This parameter is used for setting the square-wave signal for command<br />

value generator.<br />

When duration 1 is over, duration 2 starts. For this duration P-0-1157,<br />

Command value generator, duration 2 the command value generator<br />

output P-0-1150, Command value generator, command value is set to<br />

half the negative amplitude P-0-1155, Command value generator,<br />

amplitude plus offset P-0-1154, Command value generator, offset.<br />

When duration 2 is over, the output signal is set to the offset P-0-1154,<br />

Command value generator, offset until the periodic time has been<br />

reached.<br />

P-0-1200, Control word 1 velocity control<br />

Input min/max: Default value: Unit:<br />

MPB: 0 / 0x3FF 0 --<br />

In the "velocity control" mode this parameter is used to control or<br />

configure the following functions:<br />

DOK-INDRV*-FU*********-IB01-EN-P