7-40 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

Function<br />

Function<br />

See also Functional Description "Scaling of Physical Data"<br />

S-0-0086, Torque/force data scaling type<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 0 --<br />

The unit and reference of the torque/force data of a drive are set by this<br />

parameter:<br />

• percentage-based scaling (% of reference value, see below)<br />

• rotary scaling (Nm, inlbf)<br />

• linear scaling (N, lbf)<br />

See also Functional Description "Scaling of Physical Data"<br />

S-0-0091, Bipolar velocity limit value<br />

Input min/max: Default value: Unit:<br />

MPB: 10000000 S-0-0044<br />

Depending on the application, this parameter indicates the value for the<br />

maximum allowed velocity command value of the motor, independent of<br />

the sense of rotation.<br />

The maximum value for S-0-0091 is the value of "S-0-0113, Maximum<br />

motor speed". This value also is the maximum value for all other velocity<br />

parameters.<br />

Depending on the sense of rotation, the maximum velocity limit van be<br />

influenced by the parameters "S-0-0038, Positive velocity limit value" and<br />

"S-0-0039, Negative velocity limit value". These two parameters have the<br />

default value "0" and thereby are switched off, only S-0-0091 takes effect.<br />

See also Functional Description "Velocity Limitation"<br />

S-0-0092, Bipolar torque/force limit value<br />

Input min/max: Default value: Unit:<br />

MPB: 400,0 S-0-0086<br />

By this parameter it is possible to limit the torque/force command value to<br />

allowed maximum values in order to protect the mechanical components.<br />

See also Functional Description "Torque/Force Control"<br />

S-0-0093, Torque/force data scaling factor<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

This parameter is always adapting itself to the selected preferred scaling.<br />

The parameter cannot be changed!<br />

Note: Freely parameterizable scaling (parameter scaling) is<br />

impossible for the torque/force data!<br />

DOK-INDRV*-FU*********-IB01-EN-P