7-50 Commissioning and Parameterization <strong>Rexroth</strong> <strong>Indra<strong>Drive</strong></strong><br />

Function<br />

Function<br />

S-0-0401 – S-0-1000<br />

Function<br />

Function<br />

Function<br />

S-0-0383, Motor temperature<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0208<br />

This parameter indicates the measured value of the winding temperature<br />

of the motor, if the temperature sensor incorporated in the motor allows<br />

analog temperature evaluation!<br />

Note: In the case of MHD, MKD, MKE and LSF motors, the values<br />

indicated by S-0-0383 do not allow, due to the temperature<br />

sensor characteristic (switching performance), drawing a<br />

conclusion regarding the actual motor temperature!<br />

See also Functional Description "Motor Temperature Monitoring"<br />

S-0-0384, Amplifier temperature<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- S-0-0208<br />

Display parameter for the measured temperature of the controller power<br />

output stage (heat sink temperature).<br />

S-0-0520, Control word of axis controller<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- 4 --<br />

The control word of axis controller takes effect in all position-controlled<br />

operating modes and allows influencing the axis control.<br />

See also Functional Description "Operating Modes"<br />

S-0-0521, Status word of position loop<br />

Input min/max: Default value: Unit:<br />

MPB: --- / --- --- --<br />

The status word of position loop displays current information relevant to<br />

position control of the active operating mode.<br />

See also Functional Description "Operating Modes"<br />

S-0-0822, Torque/force ramp<br />

Input min/max: Default value: Unit:<br />

MPB: 0,0 S-0-0086<br />

With the torque/force ramp time (S-0-0823) the torque/force ramp defines<br />

an increase for the torque/force command value (S-0-0080) in the<br />

operating mode "torque/force control".<br />