501070099 Federal Express Oakland Sort Expansion Issued for Bid 10/11<br />

SECTION 05400 - COLD-FORMED METAL FRAMING<br />

PART 1 - GENERAL<br />

1.1 RELATED DOCUMENTS<br />

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and<br />

Division 1 Sections of these specifications, apply to this Section.<br />

1.2 SUMMARY<br />

A. This Section includes the following:<br />

1. Interior load-bearing wall framing.<br />

2. Exterior non-load-bearing wall framing.<br />

3. Ceiling joist framing.<br />

1.3 PERFORMANCE REQUIREMENTS<br />

A. Structural Performance: Provide cold-formed metal framing capable of withstanding design loads within<br />

limits and under conditions indicated.<br />

1. Design Loads: As indicated.<br />

2. Deflection Limits: Design framing systems to withstand design loads without deflections greater<br />

than the following:<br />

a. Interior Load-Bearing Wall Framing: Horizontal deflection of 1/360 of the wall height under<br />

a horizontal load of 5 lbf/sq. ft. (239 Pa) .<br />

1.4 SUBMITTALS<br />

b. Exterior Non-Load-Bearing Framing: Horizontal deflection of 1/360 of the wall height.<br />

c. Ceiling Joist Framing: Vertical deflection of 1/480 for live loads and l/360 for total loads of<br />

the span.<br />

A. Product Data: For each type of product and accessory indicated.<br />

B. Shop Drawings: Show layout, spacings, sizes, thicknesses, and types of cold-formed metal framing;<br />

fabrication; and fastening and anchorage details, including mechanical fasteners.<br />

1. For cold-formed metal framing indicated to comply with design loads, include structural analysis<br />

data signed and sealed by the qualified professional engineer responsible for their preparation.<br />

C. Welding certificates.<br />

D. Qualification data.<br />

COLD-FORMED METAL FRAMING 05400 - 1