501070099 Federal Express Oakland Sort Expansion Issued for Bid 10/11<br />

4. ASTM C 404, Specification for Aggregates for Masonry Grout.<br />

E. American Welding Society (AWS):<br />

1. ANSI/AWS D1.2, Structural Welding Code - Aluminum.<br />

1.5 SYSTEM DESCRIPTION<br />

A. Design Requirements:<br />

1. Design, fabricate and install canopies as indicated on the Drawings and as specified herein.<br />

2. Design Canopies in accordance with The Aluminum Design Manual 2000.<br />

3. Comply with the wind requirements of California Building Code - 2010.<br />

4. Provide an all welded extruded aluminum system complete with internal drainage. Non-welded<br />

systems are not acceptable.<br />

5. Provide expansion joints to accommodate temperature changes of 120 degrees F. Provide<br />

expansion joints with no metal to metal contact.<br />

6. Manufacturer’s design shall be actively and directly coordinated with Pre-Engineered Metal<br />

Building System Manufacturer to ensure adequate structural systems are provided to<br />

accommodate attachment of canopy system to the metal building system.<br />

B. Performance Requirements:<br />

1. Grout: Compressive strength of 2000 psi, minimum.<br />

1.6 SUBMITTALS<br />

A. Product Data: Manufacturer’s product information, specifications, and installation instructions for canopy<br />

components and accessories.<br />

B. Shop Drawings: Include plan dimensions, elevations, sections and details.<br />

C. Samples:<br />

1. Selection: Manufacturer’s full range of colors for the finishes selected.<br />

2. Verification: 6-inch-square samples of each finish selected on the substrate specified.<br />

D. Design Data: Design calculations bearing the seal of a Registered Professional Engineer, licensed in the<br />

state of California. Design calculations shall state that the canopy system design complies with the wind<br />

load requirements of ASCE 7and stability criteria of the California Building Code – 2010 edition, and all<br />

other governing criteria.<br />

E. Certifications:<br />

1. Manufacturer’s certification of installer.<br />

2. Manufacturer’s certification that structural members provided by metal building manufacturer’s<br />

design as depicted in their shop drawings are adequate for canopy fastening.<br />

ALUMINUM ENTRANCE CANOPIES 10730 - 2

Hooray! Your file is uploaded and ready to be published.