Show Setup Screen<br />

time, and stop date set to OFF.<br />

To run a macro every day at specific times for a specific length of time, enter a start time and date, and<br />

set the stop time and stop date to when you want the macro stopped. Leave interval set to OFF.<br />

To run a macro at specific intervals forever, enter a start time and date, set the interval to the time you<br />

want between repeats, and set the stop time and stop date to OFF.<br />

To run a macro at specific intervals for a specific length of time, enter a start time and date, set the<br />

interval to the time you want between repeats, and set the stop time and stop date to when you want<br />

the macro stopped.<br />

To run a macro only on specific days of the week during the times you have set above, uncheck the<br />

days of the week on which you don’t want it to run.<br />

MTWTFSS<br />

The day of the week (or days) on which the macro will run. The value is tick (default) if enabled or _ if<br />

disabled. The macro will be run each enabled weekday at the start time.<br />

Start Time<br />

The time of day to start the macro in 24 hour format. Can be OFF (the default) or any four digit time<br />

value (0 is midnight, 1200 is midday and 2359 is 1 minute before midnight). If this is set to OFF the<br />

macro is started at midnight on the date specified in the Start/DATE field.<br />

Start DATE<br />

The date and month to start the macro. Can be OFF (the default) or any four digit date/month number<br />

from 0101 (1st January) to 3112 (31st December). The first digit can be omitted if it is 0 (101 is the<br />

same as 0101). If this is set to OFF the macro is started today at the time specified in the Start Time<br />

field.<br />

Interval<br />

The time between repetitions of the macro. Can be OFF (the default) or any four digit time value<br />

between 0 and 23 hours, 59 minutes (2400). To run the macro once, set this to OFF. To run the macro<br />

repeatedly between the Start Time/Date and the Stop Time/Date, enter the time desired between<br />

repeats. To run the macro repeatedly forever, set a number in this field and set the Stop Time and<br />

Stop Date fields to OFF.<br />

StopTime<br />

The time of day to stop the macro in 24 hour format. Can be OFF (the default) or any four digit time<br />

value (0 is midnight, 1200 is midday and 2359 is 1 minute before midnight). If this is set to OFF the<br />

macro is stopped at midnight on the date specified in the Start Date field.<br />

Stop Date<br />

The date and month to stop the macro. Can be OFF (the default) or any four digit date/month number<br />

from 0101 (1st January) to 3112 (31st December). The first digit can be omitted if it is 0 (101 is the<br />

same as 0101). If this is set to OFF the macro is stopped today at the time specified in the Start Time<br />

field.<br />

Macro<br />