Groups<br />

maximum setting in the Console Channels group and off in the other groups. Channels can only be set<br />

to their minimum or maximum levels. Setting a channel to a non-zero value in one group sets it to its<br />

maximum level and removes it from its previous group. Regardless of which console is generating<br />

level data, all information is recorded in the main console.<br />

Grand Master 1<br />

Channels with levels in this group are controlled by Grand Master 1. All channels are initially set to FL,<br />

and can only be set to off and FL. For channels that overlap with Grand Master 2, the lower of the two<br />

output levels is used.<br />

Grand Master 2<br />

Channels with levels in this group are controlled by Grand Master 2. All channels are initially set to FL,<br />

and can only be set to off and FL. For channels that overlap with Grand Master 1, the lower of the two<br />

output levels is used.<br />

X Playback 1<br />

Channels with levels in this group are controlled by X Playback 1. All channels are initially set to FL,<br />

and can only be set to off and FL. For channels that overlap with X Playback 2, the higher of the two<br />

output levels will be used. X Playback 1<br />

X Playback 2<br />

Channels with levels in this group are controlled by X Playback 1. All channels are initially set to FL,<br />

and can only be set to off and FL. For channels that overlap with X Playback 1, the higher of the two<br />

output levels will be used.<br />

Preheat<br />

Controls the preheat level for channels if the Auto Preheat field in the Show Setup Screen is set to ON.<br />

All channels are initially off (blank level). Preheat levels for all channels are taken from this group.<br />

The Current Group<br />

The current group is the last group which has been referenced in the Group display or recorded from<br />

another display. It is shown in the right LCD, and can be used in a group selection or in group<br />

recording.<br />

All group recording commands act on a single group which is shown by # in the command description.<br />

If you do not enter a group number, the current group is used. You can use [NEXT] and [LAST]<br />

instead of # to select a group relative to the current group.<br />

[GROUP] Specifies the current group.<br />

[GROUP] [1] Specifies group 1.<br />

[GROUP] [NEXT] If the current group is group 3, this specifies group 4. If the current group is<br />

the highest group number, this specifies the lowest group number.<br />

[GROUP] [LAST] If the current group is group 3, then this specifies group 2. If the current<br />

group is the lowest group number, this specifies the highest group number.<br />

file:///C|/LIGHTP/HELP.ENG/page23.htm (3 of 11)11/2/2004 3:02:42 AM