PC Software<br />

you insufficient memory to run the software. The smartdrv command line may need<br />

editing to free more memory. The smartdrv command: SMARTDRV /S tells you how<br />

much memory is used by smartdrv. The command smartdrv in your autoexec.bat file will<br />

need modifying to change the maximum memory used. If you have 2 numbers at the<br />

end of the smartdrv command in your AUTOEXEC.BAT file, modify them to give the<br />

correct amount of memory required for the application. If you don’t have these numbers,<br />

then smartdrv will use its default values which may be too large. Change the command<br />

line to add the two numbers to the end. A typical command line for an 8M byte PC<br />

allocates 1500 kbytes as follows: C:\DOS\SMARTDRV 1500 150<br />

5. To run the OLE/Backup PC software, HIMEM.SYS must be loaded. If it is not, an error<br />

message “32rtm error: Couldn’t initialize DPMI32VM.OVL” will be given when running<br />

the software. To install HIMEM.SYS, add the line “DEVICE=HIMEM.SYS” at the top of<br />

the file C:\CONFIG.SYS using the EDIT command at DOS.<br />

6. The OLE/Backup PC software does not change the DOS PATH to include its install<br />

directory. Edit the PATH= line in the file C:\AUTOEXEC.BAT to include the software<br />

directory specified if required.<br />

7. The Properties (right mouse button) of the gp_95 or lp_95 shortcut icon can be used to<br />

fix problems. Persistent problems when running the shortcut icons can be fixed by<br />

running exclusively in MSDOS mode. To do this, bring up the shortcut Properties, select<br />

the Program tab and then the advanced button, and set MSDOS mode. This causes<br />

Win95/98 to exit automatically when the shortcut is run, and to restart when you exit the<br />

program.<br />

8. The OLE/Backup PC software will not run on a PC with a 3-COM network card<br />

connected to a non-<strong>Strand</strong> PC network. The PC must be booted off the network before<br />

running the OLE. If the network card is not a 3-COM card it may be run on the PC<br />

network<br />

9. The OLE/Backup PC software will not run under Windows3.x or Windows NT, but will<br />

run under Windows 95 and Windows 98..<br />

10. The backup PC software only works with 3-COM network cards connected to a lighting<br />

network.<br />

11. Ensure that the network configuration protocol is set up correctly in the Settings/Control<br />

Panel/Network Protocol of Windows 95/98 . You should see an item marked TCP/IP,<br />

and also a 3COM item if you are using the 3COM 3c5x9 Etherlink III card. Under TCP/IP<br />

properties, you need to specify the same IP address you set in your 220NODE.CFG file,<br />

together with a subnet mask value of 255.255.255.0. All other TCP/IP settings should be<br />

off, default or blank. The 3COM settings should show a TCP/IP binding.<br />

12. When running the software, you may get an error message saying you do not have<br />

enough memory. You must have 16Mb or more of RAM in your PC to run the software,<br />

and more than 32Mb of RAM to run the 'i' software version. If the program exits with exit<br />

code 1-99, or reports a memory error, then you need to reduce the memory used by<br />

DOS. Things to check include ram disks, disk caches (eg smartdrv), and TSR programs.<br />

13. Currently, PCs with no maths coprocessor (e.g., 486SX) do not run the software<br />

correctly. 386, 286 and 86 processors are also not suitable.<br />