Running Cues<br />

Profile<br />

F #<br />

Start the effect numbered.Refer to Product Specification for number<br />

of effects<br />

f # Stop the effect. Refer to Product Specification for number of effects<br />

The assigned Up/Down profile. You can assign separate profiles for<br />

the up and down fades.<br />

Note: The text label (caption) assigned to the cue is shown at the far right end of the second line of<br />

cue information, without a field label.<br />

Cue Properties (<strong>Lightpalette</strong>)<br />

Each cue has a number of properties, which are displayed in the Live display State screen. When the<br />

X Playback Format field in the User Setup Screen is SPREAD SHEET, the property associated with<br />

each display field is indicated by the title line. When the X Playback Format field is EXPANDED or<br />

EXPANDED - FADE TIME the fields are labelled to their left. The <strong>Lightpalette</strong> default setting for the X<br />

Playback Format field is EXPANDED.<br />

Q The recorded cue number.<br />

P The cue part (1 to 12) if it is a Tracking Cue. Otherwise blank.<br />

Time<br />

The split fade times. If not split, only the up fade time is shown. Fade<br />

times can be from one hundredth of a second to 59 minutes and 59<br />

seconds as shown for Fade Times or manual (off). The way in which<br />

fade progress and remaining time is shown depends on the X Playback<br />

Format field in the User Setup display.<br />

Wait<br />

The wait time. Blank if the wait time is off. While a cue is running, the<br />

remaining wait time appears under this value. The colour indicates its<br />

state.<br />

Delay<br />

The cue split delay times. If not split only the up fade delay is shown.<br />

Blank if there are no delays. Shows initial delay times before a cue is<br />

run, the time remaining in the delay while a cue is running, and the<br />

original delays again when the fade completes. The colour indicates<br />

their state.<br />

Link Used for cue linking and looping:<br />

file:///C|/LIGHTP/HELP.ENG/page7.htm (5 of 25)11/2/2004 3:02:36 AM