Console Reporter<br />

The log shows the date and time that each fault occurred, the rack and dimmer number and a<br />

description of the fault. The lower portion of the screen shows a map of all configured racks (max. 99)<br />

colour-coded as follows to show their status:<br />

●<br />

●<br />

●<br />

●<br />

●<br />

Green: Online<br />

Red: Fault on rack, or on one or more of its dimmers<br />

Grey: Offline<br />

(Blank): Not configured<br />

Yellow: Console is trying to find rack<br />

If a rack number is flashing, at least one dimmer in that rack is load learning.<br />

{CLEAR} Clears all logged faults, e.g., {CLEAR} [*] (command mode) or {CLEAR} {CLEAR}<br />

(direct action). Confirmation is required.<br />

{RE-SYNC} Re-synchronizes dimmer log to current rack status. E.g., {RE-SYNC} [*] (command<br />

mode) or {RE-SYNC} {RE-SYNC} (direct action)<br />

{LEARN LOAD} Used as part of command line as follows:<br />

{LEARN LOAD} {RACK} [#] [#] [*] [*]<br />