13.07.2015 Views

Unified Development Ordinance - Currituck County Government

Unified Development Ordinance - Currituck County Government

Unified Development Ordinance - Currituck County Government

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter 6: Subdivision and Infrastructure StandardsSECTION 6.2: REQUIRED INFRASTRUCTURESubsection 6.2.3: Utility Standards(g)(7,500/250 = 30), and the development would have to be locatedover 1,400 feet from an existing water main to be consideredimpractical for connection (10 units x 100) + (20 units x 20).Water lines owned by the Ocean Sands Water and Sewer Districtshall not be considered part of the county’s water supply system forthe purposes of this section.(4) Water Supply System ConfigurationThe water supply system shall comply with the following requirements:(a)(b)(c)(d)(e)(5) Connection Fees(a)(b)E. Sewage Disposal StandardsThe subdivider shall install water mains in a subdivision so that all lotsto be developed will be able to connect to the centralized watersystem.Water mains shall be installed within street right-of-ways or dedicatedutility easements.The subdivider shall be required to submit detail drawings with theconstruction drawings associated with a subdivision, prepared andstamped by a certified and licensed engineer, showing the installationof the required water mains.All materials and pipes shall meet or exceed the requirementsestablished for the county water system.A community water system may be located within an open space setaside.All connection fees shall be paid for each residential lot or use that isrequired to be connected to the county water system at the time ofissuance of the building permit authorizing construction to begin.All connection fees shall be paid for each nonresidential lot or userequired to be connected to the county water system at the time ofissuance of the building permit authorizing construction to begin.(1) Sewage System Required(a)(b)Every principal use and every buildable lot in a subdivision shall beserved by a wastewater system that complies with all AlbemarleRegional Health Services and State standards.All principal uses and buildable lots within a multi-family development,planned unit development, or planned development shall be connectedand serviced by a centralized wastewater system. The <strong>County</strong>Engineer may approve a decentralized wastewater system upon findingthat the proposed development:(i)(ii)Is not located within the service area of an existing centralizedwastewater system;Is subject to a wastewater operation and maintenance planprepared by a registered engineer that establishes sitingstandards, performance and monitoring requirements, and aroutine maintenance program; andCURRITUCK COUNTY, NC UNIFIED DEVELOPMENT ORDINANCE6.18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!