La ecuacidn (16) delinea claramenk 10s factores<br />
que reducen la eficiencia 6ptima de una turbina. La<br />
eficiencia hidr&ulica es una expresi6n de la eficacia<br />
de la paleta de una turbina en producir una variaci6n<br />
6ptima en la velocidad (tanto en magnitud <strong>com</strong>e en<br />
direcci6n a traves de la mgquina). La eficiencia<br />
mec&nica expresa las perdidas debidas a la fricci6n<br />
de 10s sellos, rodamientos y fluidos en la cubierta de1<br />
rotor, mientras que la eficiencia volumetrica es una<br />
indicaci6n de la eficacia de 10s sellos de la turbina.<br />
Semejanza<br />
Es importante considerar determinadas relaciones<br />
de semejanza para una turbina, ya que estas proporcionan<br />
informaci6n sobre ia, clase de m&quina<br />
adecuada para unit determinada serie de condiciones,<br />
proporcionan un metodo de extrapoliaci6n de 10s<br />
datos de las pruebas de1 modelo al prototipo, y permiten<br />
!a determinacidn de la eficacia de operacidn de<br />
una determinada maquina en distintas condiciones de<br />
flujo, caida y velocidad. Las maquintts menores de<br />
unos 5 a 10 MW no son generalmente objet0 de<br />
pruebas con modelos. Sin embargo, con una <strong>com</strong>prensidn<br />
adecuada de la semejanza, podemos determinar<br />
las caractetisticas operativas de una maquina<br />
pequefia a partir de datos operativos con unit maquina<br />
mayor o a partir de pruebas con modelos para<br />
una maquina analoga aunque mayor.<br />
. “.<br />
A continuaci6n reproducimos un rotor tipico de turbina.<br />
Similitude<br />
It is important to consider similarity<br />
relationships for a turbine, since these provide in-<br />
formation on the type of machine suitable for a<br />
given set of conditions, provide a method for ex-<br />
trapolation of model test data to the prototype,<br />
and allow the determination of how a given<br />
machine will operate under varying flow, head,<br />
and speed. Machines smaller than about 5 to 10<br />
MW are not generally the subject of model tests.<br />
However: with a proper understanding of<br />
similitude one can determine the operational<br />
characteristics of a small machine from<br />
operating data from a larger machine or from<br />
model tests for a similar but larger machine.<br />
A typical turbine runner is shown below.<br />
For geometrically similar devices B/D is a con-<br />
stant. The radial <strong>com</strong>ponent of the inlet<br />
velocity is<br />
(17) VR= Vt sin al = Cl sin o d2gH<br />
Thus the flow rate is simply the product of in-<br />
let area and the radial <strong>com</strong>ponent of velocity:<br />
(18) Q = (fn ; CR) D2G<br />
Figura 3 Rotor Tipico de Turbina<br />
Figure 3 Typical Turbine Runner<br />
Para dispositivos geometricamente an&logos B/D es Wherein f represents the fraction of free space in<br />
una con&ante. El <strong>com</strong>ponente radial de la velocidad the inlet passage (f m 0.95). Thus<br />
de entrada es<br />
!17) VR = VI sin al = Cl sin a Gy (19) Q = CQdgii<br />
124