diante la leccura de 10s controles el operador puede<br />

&tern-in~ !a ~nl-nral~~a -----“o de I,2 fa!la y de a!!i podrd<br />

tions. The annunciator<br />

Ir.-,-l -I,, es.4 4rr<br />

ItJG6.l &id: m =::L: ta c .ilities<br />

may be ac<strong>com</strong>panied<br />

for lnjtiating remote<br />

by a<br />

seguir instrucciones especificas de opera&h para atarm. Protective relays are mounted in a<br />

cases de falla de la planta, y con frecuencia, para separate area of the control board and are visible<br />

volver a arrancar la unidad. from the front for inspeciion of relay targets.<br />

El tablero de control consiste de medidores in- lnterposing relays are often mounted behind the<br />

dicadores, llaves de control, lutes, anunciadores, ar- control board for ease of interwiring within the<br />

reglos mimicos, relays interpuestos, relays de protec- board. Recording wattmeters, varmeters and<br />

ci6n e instrumentos indicadores. Los medidores in- voltmeters, in addition to flow and water level<br />

dicadores suministran informacih sobre el nivel de recording meters, are mcunted in the vicinity of<br />

voltaje, nivel de la Torriente, watts, voltamperios the protective relays.<br />

reactivos, temper%:da y velocidad de la unidad. Las Generator Control<br />

lutes indican estados, tales <strong>com</strong>a “bomba - conectacla<br />

Synchronization and Voltage Regulation. The<br />

“on” o desconectada “off ‘, o “vhula - abierta o ccrsynchronizing<br />

equipment allows the generator<br />

rada.” Los anunciadores not&an condiciones<br />

breaker or line breaker to be closed when the<br />

especificas de alarma o falla en toda 1s planta.<br />

generator voltage is in phase and frequency v;ith<br />

Generalmente 10s puntos anunciadores se agrupan de<br />

the system voltage. This function may be peracllerdo<br />

a la funcih. A menudo se usa un diseno que<br />

formed manually with use of a synchroscope or<br />

tiene 10s anunciadores agrupados en: generador, turautomatically<br />

employing speed-matching and<br />

bina y linea de transmisih. El anunciador puede ir<br />

automatic synchronizing relays. For small units,<br />

a<strong>com</strong>ptiado por una alarma local y faci!idades para<br />

automatic synchronizing equipment may be<br />

iniciar la alarma remota. Los rela) _ de proteccih<br />

eliminated.<br />

estin montados en un Korea separada de1 tablero de<br />

The voltage regulator works jointly with the<br />

control y son visibles desde el frente para poder instatic<br />

excitation equipment. After the field has<br />

speccionar el objetivo de1 relevador. Los reievadores<br />

interpuestos se colocan a menudo d&r& de1 tablero<br />

been excited to achieve system voltage and the<br />

de control para dar facilidad para interconeccih dengenerator<br />

is synchronized to the system, the<br />

tro de1 tablero. Los medidores que indican watts,<br />

voltage regulator assures that the set point<br />

vars y voltios adem& de 10s medidores de1 flujo y<br />

voltage is automaticslly maintained. A voltage<br />

nivel dei agua estin colocadcs en la vecindad de 10s<br />

adjustment device is provided to set the desired<br />

relevadores de protecch.<br />

generator voltage.<br />

Generator Breakers and Line Breakers.<br />

Control de1 Generador<br />

Generator breakers and line circuit breakers are<br />

the link that connects the generator to the power<br />

Regulacih y Sincronizacih de1 Yoltaje. El grid. The generator breaker closing occurs when<br />

equip0 de sincronizacih permite que el interruptor the unit is in synchronism with the power grid.<br />

de! gcnerador o el interruptor de 1a hea se cierre These breakers also act as an interrupting or<br />

cuando el generador de1 voltaje estk. en sincronizacih tripping mechanism to disconnect the unit from<br />

con la fase y la frecuencia de1 sistema, Esta funcih the system when an abnormal condition or a norse<br />

puede ejecutar manualmente con el uso de un sincroscopio<br />

o autom&ticamente empleando relevadores<br />

mal shutdown takes place.<br />

Breakers are classified by type, voltage class,<br />

autom&ticos de sincronizacibn y ajuste de la continuous rated current and interrupting capacivelocidad.<br />

Para las unidades pequefias se puede ty. Types of breakers include magnetic, air blast,<br />

eliminar e! equip0 de sincronizacih automgtica. gas, oil and vacuum and are indicative of the<br />

El regulador de voltaje trabaja en conjunto con el medium in which the electrical arc is<br />

eqcipo de esti’mulo es+&tico. Despuh de estimular el extinguished.<br />

campo para obtener el voltaje de1 sistema, y cuando Generator breakers for small and mini<br />

el generador esti sincronizado al sistema, el hydroelectric installations are <strong>com</strong>monly air blast<br />

regulador de1 voltaje asegura el mantenimiento de1 or vacuum-type, metal-clad units rated at 4.160<br />

voltaje a un punto fijo. Se suministra un dispositivo kV. The interrupting capacity is dependent on<br />

para ajustar el voltaje a fin de establecer el deseado fault calculations which determine system and<br />

voltaje de1 generador. generator contribution to a fault. Metal-clad units<br />

Interruptores de1 Generador e Interruptores de<br />

la Linea. Los interruptcres de1 generador e interrupcan<br />

be supplied with associated<br />

strument transformers.<br />

metering and in-