Small Decentralized Hydropower Program National ... - Cd3wd.com
Small Decentralized Hydropower Program National ... - Cd3wd.com
Small Decentralized Hydropower Program National ... - Cd3wd.com
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Generadores El&trims<br />
La selection y ubicacion de1 generador depende de<br />
factores tales <strong>com</strong>a el tipo de turbina y la orientation<br />
de la turbina. Por ejemplo, el generador para una<br />
turbina de tipo bulbo est.5 colocado dentro de1 mismo<br />
bulbo. Por lo general una turbina de tubo requiere un<br />
generador horizontal, y un generador con eje vertical<br />
a engranaje de empuje es adecuado para la mayoria<br />
de las instalaciones de las turbinas Francis. DOS tipos<br />
de generadores, sincronizado y a induction, seran<br />
presentados en 10s parrafos siguientes.<br />
La selection de1 generador, sincronizado o a induc-<br />
cidn, es una funcion de la aplicacion. Un generador a<br />
induction tiene un factor de energia fijo, lo cual setia<br />
una desventaja si se estuviera operand0 una ?equeAa<br />
central de energia, ya que 10s otros generadores en la<br />
central tendtian que suministrar el <strong>com</strong>ponente<br />
reactive para la o?eracih de1 generador de induc-<br />
cion. Los generadores sincronizados pueden variar el<br />
factor de energia y contribuir a la energia reactiva<br />
de las centrales. Se pueden utilizar el ajuste adecuado<br />
de 10s <strong>com</strong>ponentes de 10s genersdores sincronizados<br />
para reducir las pkdidas de las cent&es. La selec-<br />
cih se ta de basar en un analisis dc3 la red de<br />
abastecimiento de energia a la cual el generador con-<br />
tribuira la enc:gia, case por case.<br />
Sincronizado. Un generador sincronizado obtiene<br />
su nombre por estar sincronizado con el voltaje y la<br />
frecuencia de la central antes de cerrar el interruptor<br />
que conecta el generador a la centra! y cuando esti<br />
cone&ado contintia operand0 a velocidad<br />
sincronizada.<br />
Se estimula el generador mediante la aplicacih de<br />
una fuente de corriente directa (dc) a traves de1 em-<br />
bobinado de1 campo de1 rotor y la creation de un<br />
campo magnetico dentro de1 estator que induce un<br />
voltaje potential en la bobina de1 estator. Los disenos<br />
de hoy &a emplean un artefacto de estimulacion<br />
estitica que convierte una fuente de corriente alterna<br />
(ac) a dc por intermedio de un circuito de e&ado<br />
solid0 (solid state). E! sisterma est5tico ha<br />
reemplazado 10s generadores de estinxtlo de corriente<br />
directa movichs por ejes y reiativamente cuesta<br />
menos, tiene un tiempo m6s corto de reaccih y<br />
a<strong>com</strong>oda la descarga de1 campo de energia sin un<br />
resistor de1 campo de descarga cuando se necesite<br />
desconectarlo de stibito. No obstante, para 10s<br />
generadores de 5,000 o menos, a veces todatia se<br />
usan estimuladores a eje sin carbones en vez de1<br />
sistema estitico de estimular. El estimulador sin car-<br />
Electric Generators<br />
The seleclion and location of the generator is<br />
influenced by factors such as turbine type and<br />
turbine orientation. For example, the generator<br />
for a bulb-type turbine is located within the bulb<br />
itself. A horizontal qensrator is usually required<br />
ior a tube turbine ,Ay:d a vertical shaft generator<br />
with a thrust bearin is appropirate for most<br />
Francis turbine installations. Two types of<br />
generators, synchro IOUS and induction, will be<br />
discussed in the following paragraphs.<br />
The choice of generator, synchronous or induc-<br />
tion, is a function of application. An induction<br />
generator has a fixed power factor which, if<br />
operating in a small power system, can be a<br />
disadvantage because other generators in the<br />
system will be required to provide the reactive<br />
<strong>com</strong>ponent for the operation of the induction<br />
generator. Synchronous generators can vary the<br />
power factor and contribute reactive power to the<br />
system. The proper adjustment of reactive <strong>com</strong>-<br />
ponents of synchronous generators can be utiliz-<br />
ed to reduce losses in the system. Selection<br />
should bt: based on a case-by-case analysis of<br />
the power grid to which the generator will con-<br />
tribute power.<br />
Synchronors. A synchronous generator is so<br />
named because it is synchronized to the system<br />
voltage and frequency before the breaker device,<br />
which connects the generator to the system, is<br />
closed and, when connected, continues to<br />
operate at synchronous speed.<br />
The excitation of the generator is achieved by<br />
impressing a direct current (dc) source across the<br />
rotor field eoiis and creating a magnetic field<br />
within the stator which induces a voltago poten-<br />
tial in the stator coils. Present day designs<br />
employ a static excitation device which converts<br />
an alternating current (ac) source to a dc source<br />
via solid state circuitry. The static system has<br />
replaced the shaft-driven de excitation generator<br />
and <strong>com</strong>paratively costs less, has a quicker<br />
response time and ac<strong>com</strong>odates discharge of<br />
the field energy without a field discharge resistor<br />
upon a sudden disconnect of the unit from the<br />
system. However, for generators of 5,000 kW or<br />
less, a brushless shaft driven exciter may still be<br />
used in lieu of a static excitation system. The<br />
brushless exciter is a rotating ac generator with<br />
rectifiers on the main shaft to produce de cur-<br />
rent for the field.<br />
196