General-purpose timer (TIMx)<br />

RM0008<br />

Figure 134. Example of encoder interface mode with IC1FP1 polarity inverted.<br />

forward<br />

jitter<br />

backward<br />

jitter<br />

forward<br />

TI1<br />

TI2<br />

Counter<br />

down<br />

up<br />

down<br />

The timer, when configured in Encoder Interface mode provides information on the sensor’s<br />

current position. You can obtain dynamic information (speed, acceleration, deceleration) by<br />

measuring the period between two encoder events using a second timer configured in<br />

capture mode. The output of the encoder which indicates the mechanical zero can be used<br />

for this purpose. Depending on the time between two events, the counter can also be read<br />

at regular times. You can do this by latching the counter value into a third input capture<br />

register if available (then the capture signal must be periodic <strong>and</strong> can be generated by<br />

another timer). when available, it is also possible to read its value through a DMA request<br />

generated by a Real-Time clock.<br />

14.3.13 Timer input XOR function<br />

The TI1S bit in the TIM1_CR2 register, allows the input filter of channel 1 to be connected to<br />

the output of a XOR gate, combining the three input pins TIMx_CH1 to TIMx_CH3.<br />

The XOR output can be used with all the timer input functions such as trigger or input<br />

capture.<br />

An example of this feature used to interface Hall sensors is given in Section 13.3.18 on page<br />

288.<br />

14.3.14 Timers <strong>and</strong> external trigger synchronization<br />

The TIMx Timers can be synchronized with an external trigger in several modes: Reset<br />

mode, Gated mode <strong>and</strong> Trigger mode.<br />

Slave mode: Reset mode<br />

The counter <strong>and</strong> its prescaler can be reinitialized in response to an event on a trigger input.<br />

Moreover, if the URS bit from the TIMx_CR1 register is low, an update event UEV is<br />

generated. Then all the preloaded registers (TIMx_ARR, TIMx_CCRx) are updated.<br />

In the following example, the upcounter is cleared in response to a rising edge on TI1 input:<br />

● Configure the channel 1 to detect rising edges on TI1. Configure the input filter duration<br />

(in this example, we don’t need any filter, so we keep IC1F=0000). The capture<br />

prescaler is not used for triggering, so you don’t need to configure it. The CC1S bits<br />

select the input capture source only, CC1S = 01 in the TIMx_CCMR1 register. Write<br />

CC1P=0 in TIMx_CCER register to validate the polarity (<strong>and</strong> detect rising edges only).<br />

346/995 Doc ID 13902 Rev 9