RM0008<br />

Secure digital input/output interface (SDIO)<br />

the card must be selected before using it. The card lock/unlock comm<strong>and</strong>s have the<br />

structure <strong>and</strong> bus transaction types of a regular single-block write comm<strong>and</strong>. The<br />

transferred data block includes all of the required information for the comm<strong>and</strong> (the<br />

password setting mode, the PWD itself, <strong>and</strong> card lock/unlock). The comm<strong>and</strong> data block<br />

size is defined by the SDIO card host module before it sends the card lock/unlock comm<strong>and</strong>,<br />

<strong>and</strong> has the structure shown in Table 141.<br />

The bit settings are as follows:<br />

● ERASE: setting it forces an erase operation. All other bits must be zero, <strong>and</strong> only the<br />

comm<strong>and</strong> byte is sent<br />

● LOCK_UNLOCK: setting it locks the card. LOCK_UNLOCK can be set simultaneously<br />

with SET_PWD, however not with CLR_PWD<br />

● CLR_PWD: setting it clears the password data<br />

●<br />

●<br />

SET_PWD: setting it saves the password data to memory<br />

PWD_LEN: it defines the length of the password in bytes<br />

● PWD: the password (new or currently used, depending on the comm<strong>and</strong>)<br />

The following sections list the comm<strong>and</strong> sequences to set/reset a password, lock/unlock the<br />

card, <strong>and</strong> force an erase.<br />

Setting the password<br />

1. Select a card (SELECT/DESELECT_CARD, CMD7), if none is already selected.<br />

2. Define the block length (SET_BLOCKLEN, CMD16) to send, given by the 8-bit card<br />

lock/unlock mode, the 8-bit PWD_LEN, <strong>and</strong> the number of bytes of the new password.<br />

When a password replacement is done, the block size must take into account that both<br />

the old <strong>and</strong> the new passwords are sent with the comm<strong>and</strong>.<br />

3. Send LOCK/UNLOCK (CMD42) with the appropriate data block size on the data line<br />

including the 16-bit CRC. The data block indicates the mode (SET_PWD = 1), the<br />

length (PWD_LEN), <strong>and</strong> the password (PWD) itself. When a password replacement is<br />

done, the length value (PWD_LEN) includes the length of both passwords, the old <strong>and</strong><br />

the new one, <strong>and</strong> the PWD field includes the old password (currently used) followed by<br />

the new password.<br />

4. When the password is matched, the new password <strong>and</strong> its size are saved into the PWD<br />

<strong>and</strong> PWD_LEN fields, respectively. When the old password sent does not correspond<br />

(in size <strong>and</strong>/or content) to the expected password, the LOCK_UNLOCK_FAILED error<br />

bit is set in the card status register, <strong>and</strong> the password is not changed.<br />

The password length field (PWD_LEN) indicates whether a password is currently set. When<br />

this field is nonzero, there is a password set <strong>and</strong> the card locks itself after power-up. It is<br />

possible to lock the card immediately in the current power session by setting the<br />

LOCK_UNLOCK bit (while setting the password) or sending an additional comm<strong>and</strong> for card<br />

locking.<br />

Doc ID 13902 Rev 9 477/995