<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

Creating the Cascade-enabled Entry Queue<br />

The cascade-enabled Entry Queue maintains the correct behavior of the cascaded link when<br />

it dials into it.<br />

The cascade-enabled Entry Queue should be used only to connect cascaded links and should not<br />

be used to connect standard participants to conferences.<br />

When cascading High Definition (HD) conferences, the cascade-enabled Entry Queue must<br />

have the same settings as both cascaded conferences and the participants in both<br />

conferences must use the same line rate and HD capabilities as set for the conferences and<br />

Entry Queue.<br />

To define a Cascade-Enabled Entry Queue:<br />

1 In the <strong>RMX</strong> Management pane, click the Entry Queues button.<br />

The Entry Queues list pane is displayed.<br />

2 Click the New Entry Queue button.<br />

3<br />

The New Entry Queue dialog box is displayed.<br />

Define the standard Entry Queue parameters (as described in Chapter 3).<br />

4 In the Cascade field, select Master or Slave depending on the Master/Slave relationship.<br />

— Set this field to Master if the Entry Queue is defined on the MCU that is at the<br />

center of the topology and other conferences dial into it (acting as the Master).<br />

— Set this field to Slave if the Entry Queue is defined on the MCU acting as a Slave,<br />

that is, to which the link from the Master MCU (MCU at the center of the topology)<br />

is dialing.<br />

If you are defining an HD cascaded Entry Queue, it is recommended to select the same<br />

Profile that is selected for both conferences.<br />

5 Click OK.<br />