<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

Table B-1 Alarms (Continued)<br />

Alarm Code Alarm Description<br />

Incorrect Ethernet Settings Incorrect Ethernet Settings:<br />

Ethernet should be set to 100 Full Duplex, Auto Negotiation - off.<br />

Insufficient resources Insufficient resources.<br />

Insufficient UDP Ports<br />

Internal MCU reset Possible explanations:<br />

• McmsDaemon reset due to policy decision: [Process failed [abs crash<br />

counter: crash counter]: process name].<br />

• McmsDaemon reset due to policy decision: [Process failed [abs crash<br />

counter: crash counter]: process name]; Cannot reset while system is in<br />

DEBUG mode.<br />

• Power down signal was detected.<br />

• [CS Component Failure; unit type:<br />

[NonComponent\CSMngnt\CSH323\CSSIP]\CS Component Failure; unit<br />

type: (invalid: [unit type])\No connection with CS]; Cannot reset while<br />

system is in DEBUG mode.<br />

• Reset cause unknown: [reset source]\Restore Factory Defaults - [mcu<br />

restore name]\CM_Loaded indication repeated; boardId: [boardId]\reset<br />

from Cards process - simulation\No connection with MPM; board<br />

Id:[boardId]\SmMfaFailure - boardId: [boardId]. Status: [status], problem<br />

bitmask: [problemBitMask]\MPM failure, boardId: [slotId]\Switch failure\No<br />

connection with Switch.<br />

Internal System configuration during<br />

startup<br />

System configuration during startup.<br />

Invalid date and time Invalid date and time:<br />

MCU year ([year]) must be <strong>2000</strong> or later.<br />

Invalid MCU <strong>Version</strong> MCU <strong>Version</strong>: [Major.Minor.release.internal].<br />

Invalid System Configuration<br />

IP addresses of Signaling Host and<br />

Control Unit are the same<br />

IP Network Service configuration modified IP Network Service was modified.<br />

Reset the MCU.<br />

IP Network Service deleted IP Network Service was deleted.<br />

Reset the MCU.<br />

IP Network Service not found Possible explanations:<br />

• IP Service not found in the Network Services list.<br />

• m_StatusRead IpServiceList.<br />

ISDN/PSTN Network Services<br />

configuration changed<br />

License not found<br />

B-6 <strong>Polycom</strong>, Inc.