Appendix D-Ad Hoc Conferencing and External Database Authentication<br />

MCU Configuration to Communicate with an External Database Application<br />

To enable the communication with the external database application, several flags must be<br />

set in the System Configuration.<br />

To set the System Configuration flags:<br />

1 On the Setup menu, click System Configuration.<br />

The System Flags dialog box opens.<br />

2 Modify the values of the following flags:<br />

Table D-1 Flag Values for Accessing External Database Application<br />

Flag Description and Value<br />

ENABLE_EXTERNAL_<br />

DB_ACCESS<br />

3 Click OK.<br />

4 Reset the MCU for flag changes to take effect.<br />

The flag that enables the use of the external database application.<br />

EXTERNAL_DB_IP The IP address of the external database application server. default<br />

IP: 0.0.0.0.<br />

EXTERNAL_DB_POR<br />

T<br />

EXTERNAL_DB_LOGI<br />

N<br />

EXTERNAL_DB_PASS<br />

WORD<br />

EXTERNAL_DB_DIRE<br />

CTORY<br />

The port number used by the MCU to access the external<br />

application server.<br />

Default Port = 80.<br />

The user name defined in the external database application for the<br />

MCU.<br />

The password associated with the user name defined for the MCU<br />

in the external database application.<br />

The URL of the external database application.<br />