3 Login using http://.<br />

Comprehensive Restore to Factory Defaults<br />

Appendix I-Restoring Defaults<br />

Inserting a USB key containing a file named RestoreToFactoryDefault.txt and a<br />

lan.cfg file will cause the <strong>RMX</strong> to exit Secure Mode and perform a Comprehensive Restore to<br />

Factory Defaults.<br />

The Comprehensive Restore to Factory Defaults deletes the following files:<br />

• CDR<br />

• Address Book<br />

• Log Files<br />

• Faults<br />

• Dump Files<br />

• Notes<br />

In addition all the conferencing entities are deleted:<br />

• Entry Queues<br />

• Profiles<br />

• Meeting Rooms<br />

• IVR Services<br />

• Default Network IP Service<br />

• Log Files<br />

• CFS license information<br />

• Management Network Service<br />

The <strong>RMX</strong> is restored to the settings it had when shipped from the factory. The Product<br />

Activation Key is required to re-configure the Management Network Service during the First<br />

Entry Configuration.<br />

Comprehensive Restore to Factory Defaults Procedure<br />

To perform a Comprehensive Restore to Factory Defaults:<br />

Restoring the <strong>RMX</strong> to Factory Defaults consists of the following procedures:<br />

A Backup Configuration Files<br />

— These files will be used to restore the system in Procedure C.<br />

B Restore to Factory Defaults<br />

— Restart the system with a USB device containing a file named<br />

RestoreToFactoryDefault.txt and a lan.cfg file plugged into the USB port.<br />

C Optional. Restore the System Configuration From the Backup<br />

— Apply the backup file created in procedure A.<br />

— Restart the <strong>RMX</strong>.<br />

(If the <strong>RMX</strong> is unresponsive after these procedures a further restart may be necessary.)<br />