<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

3 Define the following parameters:<br />

Table 6-3: New Factory Properties<br />

Option Description<br />

Display Name Enter the SIP Factory name that will be displayed.<br />

The Display Name is the conferencing entity name in native language<br />

character sets to be displayed in the <strong>RMX</strong> Web Client.<br />

In conferences, Meeting Rooms, Entry Queues and SIP factories the<br />

system automatically generates an ASCII name for the Display Name<br />

field that can be modified using Unicode encoding.<br />

• English text uses ASCII encoding and can contain the most<br />

characters (length varies according to the field).<br />

• European and Latin text length is approximately half the length of<br />

the maximum.<br />

• Asian text length is approximately one third of the length of the<br />

maximum.<br />

The maximum length of text fields also varies according to the<br />

mixture of character sets (Unicode<br />

and ASCII).<br />

Maximum field length in ASCII is 80 characters. If the same name is<br />

already used by another conference, Meeting Room or Entry Queue,<br />

the <strong>RMX</strong> displays an error message requesting you to enter a<br />

different name.<br />

Routing Name The Routing Name is defined by the user, however if no Routing<br />

Name is entered, the system will automatically assign a new name<br />

when the Profile is saved as follows:<br />

• If an all ASCII text is entered in Display Name, it is used also as<br />

the Routing Name.<br />

• If any combination of Unicode and ASCII text (or full Unicode text)<br />

is entered in Display Name, the ID (such as Conference ID) is<br />

used as the Routing Name.<br />

Profile The default Profile is selected by default. If required, select the<br />

conference Profile from the list of Profiles defined in the MCU.<br />

A new conference is created using the parameters defined in the<br />

Profile.<br />

Automatic<br />

Connection<br />

4 Click OK.<br />

The new SIP Factory is added to the list.<br />

Select this check box to immediately accept the conference creator<br />

endpoint to the conference. If the check box is cleared, the endpoint<br />

is redirected to the conference and then connected.<br />

6-10 <strong>Polycom</strong>, Inc.