Appendix J-<strong>Polycom</strong> Open Collaboration Network (POCN)<br />

b The Port field must be set to it’s default value: 5060.<br />

(By default, the Outbound Proxy Server is the same as the SIP Server.)<br />

When configuring <strong>RMX</strong> to statically route SIP calls to DMA or CUCM, it is important to<br />

also configure the <strong>RMX</strong>’s H.323 Network Service to register with CMA gatekeeper. For<br />

more information see "Procedure 3: Configuring the <strong>RMX</strong>’s H.323 Network Service to<br />

register with CMA gatekeeper” on page J-17.<br />

Procedure 3: Configuring the <strong>RMX</strong>’s H.323 Network Service to register with<br />

CMA gatekeeper<br />

1 In the IP Network Services Properties dialog box, click the Gatekeeper tab.<br />

2 In the MCU Prefix in Gatekeeper field, enter the prefix that the <strong>RMX</strong> uses to register with<br />

the gatekeeper.<br />