<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

Table A-1 Call Disconnection Causes (Continued)<br />

Disconnection Cause Description<br />

H323 call closed. Small bandwidth The gatekeeper allocated insufficient bandwidth to the<br />

connection with the endpoint.<br />

H323 call closed. No port left There are no free ports left in the IP card.<br />

Caller not registered The calling endpoint is not registered in the gatekeeper.<br />

H323 call closed. ARQ timeout The endpoint sent an ARQ message to the gatekeeper,<br />

but the gatekeeper did not respond before timeout.<br />

H323 call closed. DRQ timeout The endpoint sent a DRQ message to the gatekeeper,<br />

but the gatekeeper did not respond before timeout.<br />

H323 call closed. Alt Gatekeeper failure An alternate gatekeeper failure occurred.<br />

H323 call closed. Gatekeeper failure A gatekeeper failure occurred.<br />

H323 call closed. Remote busy The endpoint was busy. (Applicable only to dial-out)<br />

H323 call closed. Normal The call ended normally, for example, the endpoint<br />

disconnected.<br />

H323 call closed. Remote reject The endpoint rejected the call.<br />

H323 call closed. Remote unreachable The call remained idle for more than 30 seconds and<br />

was disconnected because the destination device did<br />

not answer. Possible causes can be due to network<br />

problems, the gatekeeper could not find the endpoint's<br />

address, or the endpoint was busy or unavailable (for<br />

example, the “do not disturb” status is selected).<br />

H323 call closed. Unknown reason The reason for the disconnection is unknown, for<br />

example, the endpoint disconnected without giving a<br />

reason.<br />

H323 call closed. Faulty destination<br />

address<br />

Incorrect address format.<br />

H323 call closed. Small bandwidth The gatekeeper allocated insufficient bandwidth to the<br />

connection with the endpoint.<br />

H323 call closed. Gatekeeper reject<br />

ARQ<br />

The gatekeeper rejected the endpoint's ARQ.<br />

H323 call closed. No port left There are no ports left in the IP card.<br />

H323 call closed. Gatekeeper DRQ The gatekeeper sent a DRQ.<br />

H323 call closed. No destination IP<br />

address<br />

H323 call. Call failed prior or during the<br />

capabilities negotiation stage<br />

H323 call closed. Audio channels didn't<br />

open before timeout<br />

For internal use.<br />

The endpoint did not send its capabilities to the<br />

gatekeeper.<br />

The endpoint did not open the audio channel.<br />