Chapter 4-Cascading Conferences<br />

6 There are two methods to define the dialing string:<br />

A Using the MCU’s IP Address and the Alias string.<br />

B Using only the Alias string (requires a gatekeeper).<br />

Method A (If no gatekeeper is used):<br />

In the IP Address field, enter the IP address of the MGC hosting the destination<br />

conference (Master conference).<br />

In the Alias Name/Type field, enter the ID of the cascade-enabled Entry Queue (EQ), the<br />

Conference ID and Password of the destination conference (Master Conference) as<br />

follows:<br />

EQ ID##Destination Conference ID##Password (Password is optional).<br />

For Example: 1005##<strong>2000</strong>6##1234<br />

Cascade-enabled<br />

EQ ID<br />

Method B (Using a gatekeeper):<br />

Destination<br />

Conference ID<br />

Password (optional)<br />

In the Alias Name field, enter the MGC Prefix as registered in the gatekeeper, EQ ID,<br />

Destination Conference ID, and Password, as follows:<br />

MGC Prefix EQ ID##Conference ID##Password (Password is optional)<br />

For Example: 9251005##<strong>2000</strong>6##1234<br />

MCU Prefix as<br />

registered in the<br />

gatekeeper<br />

Cascade-enabled<br />

EQ ID<br />

Conference ID<br />

Password (optional)<br />

7 Click the Advanced tab and in the Cascade field, select the Slave option.<br />

8 Click OK.<br />

The cascade-enabled dial-out link is created and the system automatically dials out to<br />

<strong>Polycom</strong>, Inc. 4-41