Diagnostics Test Monitoring<br />

Figure 22-4 <strong>RMX</strong> 1500 Diagnostics Tests & Monitoring Tests<br />

Chapter 22-<strong>RMX</strong> Hardware Monitoring<br />

5 When the <strong>RMX</strong> enters “Diagnostics Mode”, the status MPM+/MPMx, CNTL/CNTL<br />

1500/CNTL 4000 and RTM IP/RTM IP 1500/RTM IP 4000 changes to “Diagnostics”.<br />

You can run “Diagnostics” tests on a MPM+/MPMx card by double clicking any one of<br />

the hardware components indicating “Diagnostics” in the status column.<br />

Figure 22-5 <strong>RMX</strong> <strong>2000</strong>/4000 MPMx D - DSP DSP Sub Test selection<br />

6 Select the Run all Tests box and then click Run Selected Tests.<br />

Run all Test<br />

Selection<br />

Run a “Diagnostics” test on a CTNL card by clicking the CTNL hardware component that indicates<br />

“Diagnostics” in the status column.<br />

Optional. In the Diagnostics - Active Test box you can select specific tests to run and then click Run<br />

Selected Tests.<br />

Table 22-20 Tests Selection - Additional Test Parameters<br />

Parameter Description<br />

Loop Test Enter the amount of times the test is to repeat itself in succession.<br />

Stop On Failure Stops tests upon a failure.<br />

Run All Test Runs all tests listed in the TestActive column for the hardware<br />

component.<br />