19.08.2013 Views

RMX 2000 Administrator's Guide Version 7.6.1 - Polycom

RMX 2000 Administrator's Guide Version 7.6.1 - Polycom

RMX 2000 Administrator's Guide Version 7.6.1 - Polycom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

4 In the New Value field, enter the flag’s new value.<br />

5 Click OK to close the Update Flag dialog box.<br />

6 Repeat steps 2–4 to modify additional flags.<br />

7 Click OK to close the System Flags dialog box<br />

For flag changes (including deletion) to take effect, reset the MCU. For more information see<br />

"Resetting the <strong>RMX</strong>” on page 20-67.<br />

Manually Adding and Deleting System Flags<br />

To add a flag:<br />

1 In the System Flags dialog box, click the New Flag (<br />

The New Flag dialog box is displayed.<br />

) button.<br />

2 In the New Flag field enter the flag name.<br />

3 In the Value field enter the flag value.<br />

The following flags can be manually added to the MCMS_PARAMETERS tab:<br />

Table 21-2 Manually Added System Flags – MCMS_PARAMETERS<br />

Flag Description<br />

ALWAYS_FORWARD_DTMF<br />

_IN_GW_SESSION_TO_ISD<br />

N<br />

(ISDN)<br />

When set to YES, all DTMF codes sent by participants in the<br />

GW session will be forwarded to all PSTN and ISDN<br />

participants in the same GW session.<br />

Range: YES / NO<br />

Default Value: NO<br />

21-16 <strong>Polycom</strong>, Inc.