7 Click the SIP Advanced tab.<br />

Appendix H-Setting the <strong>RMX</strong> for Integration Into Microsoft Environment<br />

8 In the ICE Environment field, select MS (for Microsoft ICE implementation) to enable the<br />

ICE integration.<br />

This field is disabled if the <strong>RMX</strong> is running in MPM Card Configuration Mode.<br />

9 In the Server User Name field, enter the <strong>RMX</strong> User name as defined in the Active<br />

Directory. For example, enter rmx111.<br />

This field is disabled if the ICE Environment field is set to None.<br />

10 Optional if the Fixed Ports options was selected previously.<br />

Click the Ports tab to modify the number of UDP Ports allocated to the calls to<br />

accommodate the number of ports required for ICE dialing.<br />

11 In the UDP Port Range, modify the number of UDP ports by enter the first and last port<br />

numbers in the range. When ICE environment is enabled, the number of ports defined<br />

in the range should be 2024.<br />

12 Click OK.<br />

The <strong>RMX</strong> will register with the OCS/Lync Server enabling automatic retrieval of the<br />

STUN server and Relay server parameters for ICE dialing.<br />

These parameters can be viewed in the Signaling Monitor - ICE Servers dialog box.<br />