Chapter 22-<strong>RMX</strong> Hardware Monitoring<br />

6. The Diagnostics Summary pane is displayed at the bottom of the Hardware Monitoring<br />

pane.<br />

Figure 22-1<strong>RMX</strong> <strong>2000</strong>/4000 Diagnostics Tests & Monitoring Tests<br />

Figure 22-2<strong>RMX</strong> 1500 Diagnostics Tests & Monitoring Tests<br />

7 Select the Run all Tests box and then click Run Selected Tests.<br />

Table 22-19 Tests Selection - Additional Test Parameters<br />

Parameter Description<br />

Loop Test Enter the amount of times the test is to repeat itself in succession.<br />

Stop On Failure Stops tests upon a failure.<br />

Run All Test Runs all tests listed in the TestActive column for the hardware<br />

component.<br />

8 The selected tests are initialized. In the Tests Monitoring pane there is an indication of<br />

the Status of the Tests.<br />

9 This process may take some time. Click Stop Running Test to end all the diagnostic tests.<br />

The MCU completes the current test running and then stops all remaining tests.<br />

10 When the Test are completed, you have the option to download a report in Excel format<br />

for analysis by your next level of support by clicking the Export Diagnostics Result<br />

button.<br />

11 The Diagnostics Mode can be exited by pressing the red System Reset icon.<br />

12 The <strong>RMX</strong> then resets.<br />

<strong>Polycom</strong>, Inc. 22-27