<strong>Polycom</strong> <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Administrator’s <strong>Guide</strong><br />

IP Network Services<br />

Two IP Services are defined for the <strong>RMX</strong>:<br />

• Management Network<br />

• Default IP Service (Conferencing Service)<br />

Dial in, dial out connections and <strong>RMX</strong> management are supported within the following IP<br />

addressing environments:<br />

• IPv6<br />

• IPv4<br />

• IPv6 & IPv4<br />

When IPv4 is selected, IPv6 fields are not displayed and conversely when IPv6 is selected,<br />

IPv4 fields are not displayed. When IPv6 & IPv4 is selected both IPv6 and IPv4 fields are<br />

displayed.<br />

For the purposes of comprehensive documentation, all screen captures in this chapter show<br />

the dialog boxes as displayed with IPv6 & IPv4 selected.<br />

For more information see "Using IPv6 Networking Addresses for <strong>RMX</strong> Internal and External<br />

Entities” on page 15-29.<br />

Management Network (Primary)<br />

The Management Network is used to control the <strong>RMX</strong>, mainly via the <strong>RMX</strong> Web Client<br />

application. The Management Network contains the network parameters, such as the IP<br />

address of the Control Unit, needed for connection between the <strong>RMX</strong> and the <strong>RMX</strong> Web<br />

Client. This IP address can be used by the administrator or service personnel to connect to<br />

the Control Unit should the <strong>RMX</strong> become corrupted or inaccessible.<br />

During First Time Power-up, the Management Network parameters can be set either via a USB<br />

key or by using a cable to create a private network.<br />

For more information, see the <strong>RMX</strong> 1500/<strong>2000</strong>/4000 Getting Started <strong>Guide</strong>, "Modifying the<br />

Factory Default Management Network Settings on the USB Key” on page 2-7 and Appendix G of<br />

this manual, "Configuring Direct Connections to <strong>RMX</strong>” on page G-1.<br />

Default IP Service (Conferencing Service)<br />

The Default IP Service (Conferencing Service) is used to configure and manage<br />

communications between the <strong>RMX</strong> and conferencing devices such as endpoints,<br />

gatekeepers, SIP servers, etc.<br />

The Default IP Service contains parameters for:<br />

• Signaling Host IP Address<br />

• MPM, MPM+ and MPMx media cards (Media Processors<br />

• External conferencing devices<br />

Calls from all external IP entities are made to the Signaling Host, which initiates call set-up<br />

and assigns the call to the appropriate MPM / MPM+ / MPMx media card.<br />

From <strong>Version</strong> 7.1, MPM media cards are not supported.<br />