Alarms and Faults<br />

Alarms<br />

Table B-1 Alarms<br />

Alarm Code Alarm Description<br />

A new activation key was loaded. Reset<br />

the system.<br />

A new version was installed. Reset the<br />

system.<br />

A new activation key was loaded:<br />

Reset the MCU.<br />

A new version was installed:<br />

Reset the MCU.<br />

Appendix B<br />

A private version is loaded A private version is loaded: [private description].<br />

Action redirection failure Possible explanations:<br />

• Action redirection failure.<br />

• Action redirection map incomplete.<br />

Alarm generated by a Central Signaling<br />

component<br />

Alarm generated by an internal<br />

component<br />

Automatic reset is unavailable in Safe<br />

Mode<br />

A system alert was generated by a component of the Central Signaling.<br />

A system alert was generated by an internal system component.<br />

The system switches to safe mode if many resets occur during startup. To<br />

prevent additional resets, and allow the system to complete the startup<br />

process the automatic system resets are blocked.<br />

Backup of audit files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default<br />

setting when ULTRA_SECURE_MODE System Flag is set to YES) and a<br />

Cyclic File reaches a file retention time or file storage capacity limit, the user is<br />

alerted that audit files need to be backed up.<br />

Backup of CDR files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default<br />

setting when ULTRA_SECURE_MODE System Flag is set to YES) and a<br />

Cyclic File reaches a file retention time or file storage capacity limit, the user is<br />

alerted that CDR files need to be backed up.<br />

Backup of log files is required If the ENABLE_CYCLIC_FILE_SYSTEM_ALARMS is set to YES (default<br />

setting when ULTRA_SECURE_MODE System Flag is set to YES) and a<br />

Cyclic File reaches a file retention time or file storage capacity limit, the user is<br />

alerted that log files need to be backed up.<br />

Bios version is not compatible with Ultra<br />

Secure Mode.<br />

Card failed to switch to Ultra Secure<br />

Mode<br />

The current BIOS version is not compatible with Ultra Secure Mode<br />

(ULTRA_SECURE_MODE=YES).<br />

Card failure occurred when the system was set to Enhance Security Mode<br />

(ULTRA_SECURE_MODE=YES).<br />