Chapter 4-Cascading Conferences<br />

— Master, if the participant is defined in a conference running on the Master MCU.<br />

6 Click OK.<br />

MGC to <strong>RMX</strong> Cascading<br />

Level 1 (Master) Level 2 (Slave to Level 1)<br />

MGC running versions other than 9.0.4 is always on level 1 and must be set as the Master<br />

MCU. If the cascading topology includes additional MGCs as well as <strong>RMX</strong>s it is<br />

recommended to define Video Switching conferences for all the cascading conferences in the<br />

topology.<br />

If MGC is running version 9.0.4, and <strong>RMX</strong> is running version 7.0.2 and higher, the MGC can<br />

be set as Master on level 1 and MGC as Slave on level 2<br />

Depending on the dialing direction, the following procedures must be performed:<br />

Table 4-7 Set up Procedures according to the Dialing Direction<br />

Dialing<br />

Direction<br />

MGC Level 1<br />

MGC to <strong>RMX</strong> Set the appropriate flags (done once<br />

only).<br />

Define the conference setting and<br />

its line rate to be the same as the<br />

one set on the <strong>RMX</strong>.<br />

Define the dial-out participant<br />

(Cascaded Link) to the conference<br />

running on the <strong>RMX</strong>.<br />

<strong>RMX</strong> to MGC Set the appropriate flags (done once<br />

only)<br />

Define the cascade-enabled Entry<br />

Queue.<br />

Define the conference setting and<br />

its line rate to be the same as the<br />

one set on the <strong>RMX</strong>.<br />

<strong>RMX</strong> 1500/<strong>2000</strong>/4000<br />

Level 2<br />

Set the appropriate flags (done once<br />

only).<br />

Define the cascade-enabled Entry<br />

Queue, setting it as Slave.<br />

Define the conference setting and its line<br />

rate to be the same as the one set on the<br />

MGC.<br />

Set the appropriate flags (done once<br />

only)<br />

Define the conference setting and its line<br />

rate to be the same as the one set on the<br />

MGC.<br />

Define the dial-out participant (Cascaded<br />

Link) to the conference running on the<br />

MGC, setting the participant Cascade<br />

parameter to Slave.<br />

<strong>Polycom</strong>, Inc. 4-35