JSN M7435<br />

Name Light, Overbed, Direct And Indirect<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6230<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical F | Special electrical requirements<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 2<br />

Amps2 0<br />

Weight (lbs) 29 Weight (kgs) 14<br />

Height (in) 9 Height (cen) 23<br />

Width (in) 40 Width (cen) 102<br />

Depth (in) 11 Depth (cen) 28<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 240<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Overbed patient room light which provides direct light for patient activity and indirect light for patient examination. <strong>The</strong> indirect portion<br />

of the light can be flipped down or redirected to provide dual intensity direct lighting. Unit is fully enclosed and is available in varying<br />

lengths. Some units feature a controlled power shut off to the light and patient bed when bumped by any item. Unit is designed to be<br />

wired directly to a junction box in the wall, a headwall service rail or patient service column. Dimensions are for a three foot light.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />