JSN D3550<br />

Name Evacuation System, Laboratory, Dental<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 230<br />

Utility2: Electrical G | 208/220 volt, 3 phase<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 3<br />

Phase2 0<br />

Amps1 30<br />

Amps2 0<br />

Weight (lbs) 630 Weight (kgs) 286<br />

Height (in) 112 Height (cen) 284<br />

Width (in) 50 Width (cen) 127<br />

Depth (in) 36 Depth (cen) 91<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 11951<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

High vacuum laboratory evacuation station. <strong>The</strong> system is used in dental laboratories to provide a vacuum for up to twelve 3 inch suction<br />

inlets throughout the laboratory. <strong>The</strong> unit has a suction capacity of 1800 cubic feet per minute.<br />

JSN D3560<br />

Name Curing Unit, Denture, 2 Stage<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520005977749<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 220<br />

Utility2: Electrical C | 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 1<br />

Amps1 12<br />

Amps2 10<br />

Weight (lbs) 46 Weight (kgs) 21<br />

Height (in) 19 Height (cen) 48<br />

Width (in) 15 Width (cen) 38<br />

Depth (in) 20 Depth (cen) 51<br />

Volts2 115<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2640<br />

Watts2 1150<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Two stage denture curing unit. <strong>The</strong> unit is used in dental laboratories to polymerize heat cured denture resins. <strong>The</strong> unit is a two stage,<br />

two flask minimum capacity unit with a temperature range of 90 to 212 degrees Fahrenheit. <strong>The</strong> unit timer ranges from 15 minutes to 23<br />

hours and automatically shuts the unit off at the completion of its cycle. <strong>The</strong> oven has a safety thermostat to preclude hazardous<br />

temperature levels. <strong>The</strong> unit also has removable covers and tanks.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />