05.04.2013 Views

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

MIL-STD 1691 Master Equipment List - The Whole Building Design ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

JSN L1076<br />

Name Bath, Water, Plasma Thawing, Rapid<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing A | Hot and cold water<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 75 Weight (kgs) 34<br />

Height (in) 23 Height (cen) 58<br />

Width (in) 29 Width (cen) 74<br />

Depth (in) 23 Depth (cen) 58<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 1800<br />

Watts2<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Rapid blood thawing unit which reduces the amount of plasma that must be thawed in advance. Uses both controlled temperature and<br />

agitation to reduce thaw times. Baskets agitate the units in approximately 36C degree water for optimal heat transfer.<br />

JSN L1080<br />

Name Analyzer, Chemistry, Multichannel<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing E | Treated water and drain<br />

Volts1 220<br />

Utility2: Electrical D | 120 and 208/220 volt<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 1<br />

Amps1 20<br />

Amps2 7<br />

Weight (lbs) 1573 Weight (kgs) 715<br />

Height (in) 62 Height (cen) 157<br />

Width (in) 93 Width (cen) 236<br />

Depth (in) 41 Depth (cen) 104<br />

Volts2 120<br />

Hertz 60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 7200<br />

Watts1 4400<br />

Watts2 840<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Laboratory chemistry analyzer. <strong>The</strong> unit is capable of at least 23 chemistries including electrolytes by ISE (ion-selective electrode). <strong>The</strong><br />

analyzer can perform any combination of tests, panels or stats on a given sample. <strong>The</strong> unit has automatic QC and maintenance functions.<br />

<strong>The</strong> instrument is programmable for as many as 400 patient samples.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />