JSN D0881<br />

Name Hood, Fishmouth<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Weight (lbs) 5 Weight (kgs) 3<br />

Height (in) 15 Height (cen) 38<br />

Width (in) 8 Width (cen) 20<br />

Depth (in) 15 Depth (cen) 38<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Fish-mouth shaped hood for attachment to a vacuum system in a dental laboratory. <strong>The</strong> hood is designed to fit around a grinding or<br />

polishing wheel mounted to an electric motor. <strong>The</strong> hood shapes the air flow around the wheel so the metal and dust particles spun from<br />

the wheel are sucked into the bench or central vacuum system.<br />

JSN D0900<br />

Amps1<br />

Amps2<br />

BTU / Hour<br />

Watts1<br />

Watts2<br />

Name Workstation, Dental Lab, Receiving<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 0<br />

Utility2: Electrical . |<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Modular workstation for receiving supplies in a dental laboratory. <strong>The</strong> unit stands on the floor and consists of a 24" wide base cabinet<br />

unit with 4 drawers, a 24" wide single or double door base cabinet unit with an adjustable shelf and a 74" wide laminate counter<br />

supported by the two base cabinets. <strong>The</strong> working space between the two cabinets contains an undercounter single drawer unit.<br />

A<br />

A<br />

A<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 460 Weight (kgs) 209<br />

Height (in) 34 Height (cen) 86<br />

Width (in) 74 Width (cen) 188<br />

Depth (in) 24 Depth (cen) 61<br />

Volts2 0<br />

Hertz<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />