JSN L2325<br />

Name Cabinet, Bio Safety, Class II/B1, F/S, Vert, 6ft<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6640<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas B | Vacuum<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc E | Vent to atmosphere<br />

Phase1 1<br />

Phase2 0<br />

Amps1 16<br />

Amps2 0<br />

Weight (lbs) 1175 Weight (kgs) 534<br />

Height (in) 95 Height (cen) 241<br />

Width (in) 78 Width (cen) 198<br />

Depth (in) 34 Depth (cen) 86<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1920<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Laboratory <strong>Equipment</strong><br />

Class II, type B1, bio-safety cabinet. This is a vertical, free standing unit. <strong>The</strong> interior work surfaces are constructed of type 304 stainless<br />

steel and the exterior is 16 gauge or heavier steel. <strong>The</strong> unit utilizes 30% recirculated air and 70% direct exhaust through an in-house duct<br />

system with a face velocity of 100 fpm and has an audible alarm when window is at an unsafe level. It includes a duplex receptacle for<br />

grounded plugs and two HEPA filters zero-probed. Used for low to moderate risk biological agents treated with minute quantities of<br />

toxic chemicals and trace amounts of radionuclides. A 6 foot model is presented, other sizes are available.<br />