JSN D7090<br />

Name Utility Center, Dental, Wall or Floor Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy B | Government Furnished, Contractor Installed<br />

USAF B | Government Furnished, Contractor Installed<br />

VA B | Government Furnished, Contractor Installed<br />

IHS B | Government Furnished, Contractor Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing B | Cold water and drain<br />

Volts1 0<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas H | Vacuum and HP air (85 PSIG) minimum<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 0<br />

Phase2 0<br />

Amps1 0<br />

Amps2 0<br />

Weight (lbs) 10 Weight (kgs) 5<br />

Height (in) 6 Height (cen) 15<br />

Width (in) 15 Width (cen) 38<br />

Depth (in) 18 Depth (cen) 46<br />

Volts2 0<br />

Hertz 0<br />

Hertz Dep 0<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 0<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Utility center. <strong>The</strong> unit contains electrical and quick connect air, waste and water utility connections. <strong>The</strong> center accommodates one<br />

umbilical and includes shut-off valves and regulators for both the air and water supplies.<br />

JSN D8060<br />

Name Furnace, Porcelain, Vacuum<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6520<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing . |<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 15<br />

Amps2 0<br />

Weight (lbs) 66 Weight (kgs) 30<br />

Height (in) 23 Height (cen) 58<br />

Width (in) 15 Width (cen) 38<br />

Depth (in) 18 Depth (cen) 46<br />

Volts2 0<br />

Hertz 50/60<br />

Hertz Dep 0<br />

Hertz Switch -1<br />

BTU / Hour 0<br />

Watts1 1800<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Dental <strong>Equipment</strong> and Dental Casework<br />

Vacuum porcelain furnace. Used in dental laboratories to fire porcelain molds for dental appliances. Unit shall include a vacuum pump<br />

capable of producing 27 inches of mercury in thirty seconds.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />