JSN M8035<br />

Name Whirlpool, Arm, Pedestal Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530007103005<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 120<br />

Utility2: Electrical A | 120 volt, conventional outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 0<br />

Amps1 9<br />

Amps2 0<br />

Weight (lbs) 97 Weight (kgs) 44<br />

Height (in) 60 Height (cen) 152<br />

Width (in) 16 Width (cen) 41<br />

Depth (in) 28 Depth (cen) 71<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 1080<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Pedestal mounted arm whirlpool. Freestanding fixed height unit with stainless steel tank, flow control valve and turbine ejector-aerator.<br />

Unit may require a ground fault interrupt power circuit and may use a thermostatic mixing valve for controlling water temperature when<br />

filling.<br />

JSN M8040<br />

Name Whirlpool, Extremity, Floor Mounted<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army A | Contractor Furnished, Contractor Installed<br />

Navy A | Contractor Furnished, Contractor Installed<br />

USAF A | Contractor Furnished, Contractor Installed<br />

VA A | Contractor Furnished, Contractor Installed<br />

IHS A | Contractor Furnished, Contractor Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing D | Cold and hot water and drain<br />

Volts1 115<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc A | Earth ground<br />

Phase1 1<br />

Phase2 0<br />

Amps1 8<br />

Amps2 0<br />

Weight (lbs) 395 Weight (kgs) 180<br />

Height (in) 52 Height (cen) 132<br />

Width (in) 16 Width (cen) 41<br />

Depth (in) 32 Depth (cen) 81<br />

Volts2 0<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 920<br />

Watts2 0<br />

Description<br />

Unit of Issue EA<br />

Group Miscellaneous<br />

Floor mounted extremity whirlpool. Unit has a corrosion-resistant stainless steel tank, thermostatic water mixing console and an overflow<br />

drain. <strong>The</strong> whirlpool can be easily recessed into the floor or mounted on a pedestal. <strong>The</strong> unit is used for water hydromassage of arms,<br />

legs and other extremities. Weight shown is for a filled whirlpool.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />