JSN S2620<br />

Name Pasteurizer, Vertical Rotation<br />

Logistical Category (LOGCAT) Fund Source Weights and Measures (Typical Only)<br />

Army C | Government Furnished, Government Installed<br />

Navy C | Government Furnished, Government Installed<br />

USAF C | Government Furnished, Government Installed<br />

VA C | Government Furnished, Government Installed<br />

IHS C | Government Furnished, Government Installed<br />

Utilities<br />

NSN 6530<br />

NOTE: Values shown are based on standard typicals used for programming purposes. <strong>The</strong> contractor remains responsible to<br />

develop and coordinate the design / construction in accordance with actual equipment selection.<br />

Utility1: Plumbing C | Hot water and drain<br />

Volts1 120<br />

Utility2: Electrical B | 120 volt, special outlet<br />

Utility3: Med Gas . |<br />

Utility4: Misc Gas . |<br />

Utility5: Non-Med Gas . |<br />

Utility6: Misc . |<br />

Phase1 1<br />

Phase2 3<br />

Amps1 20<br />

Amps2 25<br />

Weight (lbs) 550 Weight (kgs) 250<br />

Height (in) 65 Height (cen) 165<br />

Width (in) 30 Width (cen) 76<br />

Depth (in) 32 Depth (cen) 81<br />

Volts2 208<br />

Hertz 60<br />

Hertz Dep -1<br />

Hertz Switch 0<br />

BTU / Hour 0<br />

Watts1 2400<br />

Watts2 9007<br />

Description<br />

Unit of Issue EA<br />

Group Sterilizers and Associated <strong>Equipment</strong><br />

A vertical rotation pasteurizer with baskets and temperature recorder. Unit features: thermostatically controlled water temperature;<br />

automatic cycles; audible and visual signal at end of cycle; power hoist; liquid level control; and a 2.5 cubic foot load capacity. Used for<br />

pasteurization (a means of high-level disinfection to kill pathogenic vegetative bacteria and viruses by total immersion in water at 160°-<br />

170°F for 30 minutes) of breathing circuit parts used by respiratory care and anesthesia departments.<br />

Thursday, April 21, 2011 <strong>MIL</strong>-<strong>STD</strong> <strong>1691</strong> | PPMD<br />